跳至主要内容

Difference Between PP And SMS Nonwovens

 Medical non-woven fabrics, the commonly used polymer material is PP, that is, polypropylene as a raw material spinneret made of non woven fabrics, because PP has no hydrophilic group, so the surface of non-woven fabrics should be sprayed with a very small amount of 0.5% hydrophilic oil agent.

Difference between PP and SMS Nonwovens (PP S2040)
 
The material is made of fibers.
 
The full name of PP is polypropylene, and the Chinese name is polypropylene. NW is short for Nonwoven, which is either nonwoven or nonwoven. Is the fiber through the air flow or machinery into a net, and then after spunlaced, acupuncture, or hot rolling reinforcement after finishing the formation of no woven cloth.
 
PPNW stands for nonwoven fabric made of PP fiber. Due to the nature of PP itself, the cloth after the performance is strong, but the hydrophilicity is poor. The usual process flow of PPNW is spinning into mesh and hot rolling reinforcement. PPNW is widely used in sterilization pouches, surgical protective gown, industrial cloth, etc.
 
SMS non-woven fabric (English :Spunbond+Meltblown+Spunbond
 
Nonwovens is a composite nonwoven fabric, which is a composite product of spunbonded and melt-blown. It has the advantages of high strength, good filtration performance, no adhesive, non-toxic and so on. At present, it is mainly used for medical and health labor protection products, such as surgical gowns, surgical caps, protective gowns, hand washing gowns, handbags, etc.
 
S stands for spunbond, which translates into spunbonded non woven fabric in Chinese; M stands for Meltblown, Chinese translation of Meltblown non-woven cloth. In the process of non-woven fabric, there is a sandwich structure material called SMS, which is a spunbonded meltblown spunbonded structure. This material combines the characteristics of strong spunbonded fabric and good barrier of meltblown fabric, and is often used in medical medical materials. We don't use the abbreviations you mentioned.
 
SMP, I think it's spunbond melt-blown composite, using PP material.
 
SM is for Spunmelt.
 
SSPP is spunbond, with PP material. In general, SS is the representation of two layers of spunbond.
 
1. Changes in internal microscopic properties occur after antivirus
 
The main material of medical nonwoven fabric is polypropylene, which is processed through melt-blown and spunbonded process through multiple processes, and its microstructure is fine plastic fiber. Shrinkage after high temperature is the characteristics of plastic goods, high temperature resistant plastic is not, and high temperature resistance is also a relative concept, so it will also have the corresponding shrinkage reaction on the micro.
 
2. Aseptic barrier performance is lost after use
 
According to research, the shelf life of sterile articles is closely related to the thickness and the number of coating layers of medical non woven fabric. After a series of high-temperature steam antivirus and chemical washing, the fiber structure is deformed, the hole is sparse, the thickness is reduced, and even the small hole is not detectable to the naked eye. The bacteria resistance rate will suddenly decrease, or the bacteria resistance performance will be lost.
 
So used medical non-woven fabric, no matter use how long, no matter use what it made things, those who use shall be thrown away after using, because the hospital many germs, doctors in treating patients are using it will unknowingly brought many germs, so in order to cut off the route of transmission, prevent infection, who used shall be disposed of, It can no longer be used.

评论

此博客中的热门博文

Reference Standard For Seal Verification of Sterilization Pouches For Medical Devices

With the increasing demand for  sterilization pouches  of medical devices, quality and safety inspection have become more and more stringent. sterilization pouches of medical devices (blister box +  tyvek roll  material,  sterilization paper bag , etc.) as a form of packaging directly in contact with the device and used to block microorganisms. No matter what form of packaging, it has two characteristics, which can meet the sterilization operation and remain sterile until the transportation conditions are used. Therefore, relevant departments began to focus on the review requirements of sterile packaging and make specific requirements for its performance and quality.   As we all know, GB/ t19633-2005 "packaging of ultimately sterilized medical devices" is one of the authoritative standards in the current sterile packaging standards. It is equivalent to iso11607-2003 "packaging of ultimately sterilized medical devices". Clarify the basic performance req...

Definition And Use Of Sterilization Or Chemical Indicator

  Sterilization indicator  tape and label   Definition: Wrinkle paper or label paper as the base material, coated with color-changing ink as sterilization indicator, back coated with pressure sensitive adhesive.  The indicating tape used for chemical monitoring outside the pressure steam  sterilization package , when reaching certain sterilization conditions 121℃, 20 minutes or 132℃, 3 minutes, the chemical indicating stripe on the back base of wrinkled paper will change from light yellow to black.   USES:   1. Used to mark whether the package has been treated by pressure steam sterilization process.   2. If the discoloration is uneven or incomplete, it may indicate that the package has not been sterilized in accordance with the conditions.   3, wrap the parcel (if no sealing tape is used).   4, sterilization information can be recorded (operator, sterilization period, item name, pot, etc.).   Chemical instruction card for...

Correctly Identify Discoloration of Chemical Indicator Cards

  01   Sterilization pouches   requirements   Why packaging   After a proper sterilization process, the apparatus in the sterilization room should be sterile, but when the apparatus is removed from the sterilization room, the outdoor air contains dust particles and microorganisms   If the device is not packaged, it will soon be contaminated   In addition, sterile items usually need to be stored for a period of time and sent to the department in need, so the equipment must be properly packaged to prevent re-contamination   Sterilization packaging  management requirements   Packaging purpose:   Extend the effect of sterilization to ensure that sterile equipment and articles can remain sterile before use.   Strict packaging requirements:   Surgical instruments use closed packaging method, generally 2 layers of packaging materials.  Closed type packaging application of special tape, tight sealing package.  ...