Reference Standard For Seal Verification of Sterilization Pouches For Medical Devices

With the increasing demand for sterilization pouches of medical devices, quality and safety inspection have become more and more stringent. sterilization pouches of medical devices (blister box + tyvek roll material, sterilization paper bag, etc.) as a form of packaging directly in contact with the device and used to block microorganisms. No matter what form of packaging, it has two characteristics, which can meet the sterilization operation and remain sterile until the transportation conditions are used. Therefore, relevant departments began to focus on the review requirements of sterile packaging and make specific requirements for its performance and quality.
 
As we all know, GB/ t19633-2005 "packaging of ultimately sterilized medical devices" is one of the authoritative standards in the current sterile packaging standards. It is equivalent to iso11607-2003 "packaging of ultimately sterilized medical devices". Clarify the basic performance requirements of sterile packaging: biocompatibility of raw materials, chemical toxicity, microbial barrier, sealing closure, aging, etc. The mentioned tightness is a key factor affecting the whole aseptic barrier system, and its failure will mean that the aseptic state is destroyed, which will largely lead to medical errors.
 
Reference standard for seal verification of sterilization pouches for medical devices
 
GB/ t19633-2005 packaging of final sterilized medical devices clearly stipulates that the sealing strength is one of the safety verification items that cannot be ignored. The two test methods proposed are tensile seal strength test and bursting/creep test. The tensile seal test of sterilized package is mainly to test its sealing strength by pulling force. The bursting/creep test evaluates the overall minimum seal strength of the sterile packaging by pressurizing the package to the point of rupture or to the critical point and holding it for a period of time. Since this method is not described in detail in the standard, it is necessary to refer to ASTM F 1140, YY/T 0681 and ASTM F 8806.

评论

  1. The Protective Eye Charm bracelet features a striking evil eye design, known for symbolizing protection and warding off negativity. This elegant piece not only enhances your style but also offers spiritual defense, combining mystical charm with contemporary fashion. Adorned with intricate details, it serves as a stylish amulet, empowering you with positive energy and a profound sense of security wherever you go. Ideal for those who appreciate accessories with both beauty and deeper meaning, this bracelet adds a touch of elegance and protective power to any outfit.

    回复删除
  2. This information is very best helpful for us Exquisite Chevron Cut Rose Gold Diamond Ring

    回复删除
  3. Really Very Nice Post. MBA in Sustainability Entrepreneurship

    回复删除

发表评论

此博客中的热门博文

Definition And Use Of Sterilization Or Chemical Indicator

  Sterilization indicator  tape and label   Definition: Wrinkle paper or label paper as the base material, coated with color-changing ink as sterilization indicator, back coated with pressure sensitive adhesive.  The indicating tape used for chemical monitoring outside the pressure steam  sterilization package , when reaching certain sterilization conditions 121℃, 20 minutes or 132℃, 3 minutes, the chemical indicating stripe on the back base of wrinkled paper will change from light yellow to black.   USES:   1. Used to mark whether the package has been treated by pressure steam sterilization process.   2. If the discoloration is uneven or incomplete, it may indicate that the package has not been sterilized in accordance with the conditions.   3, wrap the parcel (if no sealing tape is used).   4, sterilization information can be recorded (operator, sterilization period, item name, pot, etc.).   Chemical instruction card for...

Correctly Identify Discoloration of Chemical Indicator Cards

  01   Sterilization pouches   requirements   Why packaging   After a proper sterilization process, the apparatus in the sterilization room should be sterile, but when the apparatus is removed from the sterilization room, the outdoor air contains dust particles and microorganisms   If the device is not packaged, it will soon be contaminated   In addition, sterile items usually need to be stored for a period of time and sent to the department in need, so the equipment must be properly packaged to prevent re-contamination   Sterilization packaging  management requirements   Packaging purpose:   Extend the effect of sterilization to ensure that sterile equipment and articles can remain sterile before use.   Strict packaging requirements:   Surgical instruments use closed packaging method, generally 2 layers of packaging materials.  Closed type packaging application of special tape, tight sealing package.  ...